Filter Results By:

Products

Applications

Manufacturers

Showing results: 346 - 360 of 605 items found.

  • Series Standard HV Capacitors

    PMT10000 - Power Measurement Technologies Inc.

    High voltage, low dissipation factor, gas-filled Standard Capacitors for indoor use in a laboratory or production environment. A three terminal design configuration allows accurate measurements of capacitance and dissipation factor (tangent delta) with little or no effect from test lead or stray capacitance.

  • Circuit Breaker Analyzer

    CBA 1000 - Altanova Group

    CBA 1000 circuit breaker timing test equipment is a reliable and very accurate operating device for the maintenance and commissioning of circuit breakers in medium and high voltage substation. It can perform static and dynamic contact resistance measurement and it’s an accurate timing speed and motion analyzer.

  • Cable Fault Locator System

    Kvtester Electronics Technology Co.,Ltd

    To test the HV arcing fault of cable, earthing high &low resistance, short circuit and breakage of the cable, poor contact, etc. If equipped with fault locator, it can decide the exact broken position of the cable ,applies to power cable in various type, voltage and communication cable

  • Transformer Ratio Meters

    Handheld Turns Ratio & Winding Resistance Tester TWR-H - Amperis sl

    TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.

  • Professional Level Digital Clamp-on DC/AC AMmeter / Multimeter

    HH2002 - Colluck Company Limited

    CAT II 600V Raled. Basic Accuracy 1%. 3-3/4 digil Large LCD display 4000 count with symbolic signs. Auto Ranging High Voltage test up to 600V DC and 600V TRMS AC. Higher Current test up to 600A AC/DC. Continuity check. Measure Resistance. Measure Frequency. Measure Temperature

  • SpikeSafe DC Current Sources

    Vektrex Electronic Systems

    The Vektrex SpikeSafe DC Current Sources provide reliable drive for LED/laser diode reliability, IESNA LM-80 test, and other current-driven test applications. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, precise current, and high power density — typically 6.4kW-8kW.

  • 200 A HIGH-CURRENT MICRO-OHMMETER

    MPK-203x - MEGABRAS srl

    The MPK-203x high-current micro-ohmmeter is a portable, microprocessor-controlled instrument. Has optimized filters and protections for measurements in electrical substations. Can be used to accurately measure very low contact resistances of high voltage circuit-breakers and switches, busbars, etc., with test currents up to 200A. It employs the 4 terminals-method (U/I measuring principle) to avoid errors caused by test leads and their contact resistances.

  • Primary Injection Test Systems

    Megger Group Ltd.

    Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.

  • Test Board For QSFP28 Transceiver

    EQSFP28 - Optellent, Inc.

    The OPTELLENT EQSFP28 is a cost-effective and convenient test board for testing QSFP28 optical transceivers in R&D and manufacturing environments. The EQSFP28 is equipped with high quality RF connectors for data signals and test points for low frequency control and status signals. The EQSFP28 is equipped with power supplies to enable voltage margining. Key status signals are displayed using LED indicators.

  • Test Board For QSFP+ Transceiver

    EQSFP10 - Optellent, Inc.

    The OPTELLENT EQSFP10 is a cost-effective and convenient test board for testing QSFP/QSFP+ optical transceivers in R&D and manufacturing environments. The EQSFP10 is equipped with high quality RF connectors for data signals and test points for low frequency control and status signals. The EQSFP10 is equipped with power supplies to enable voltage margining. Key status signals are displayed using LED indicators.

  • Primary Injection Test Systems

    Megger Group Ltd.

    Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.

  • Personal Safety Voltage Detector

    388 SVD - Standard Electric Works Co., Ltd

    ● Warning Proximity of AC Voltage (240V~69kV). ● Protection class: IP65.● Easy-to-wear on body or belt. ● Ultra high bright LED indication.● High pitch sound indication.● The sound level can reach up to 90dB.● Test & diagnostic circuitry.● Friendly priority alert reporting. ● Circuit test function.● High impact type casing.● Different alerting sound & light.● Meets EN 61326-1.● Dimension : 114(L) × 67(W) × 27(D)mm● Weight : Approx. 152g (battery included)● Power supply : 9V(6F22) × 1

  • Teraohmmeter/IR Tester

    98x - Vitrek Corporation

    The new 981i and 983i Teraohmmeters are designed to tackle the toughest High Resistance measurement applications. Demanding applications that most other IR testers won’t measure up to. So when it’s time to test higher voltage IR values like today’s electric vehicle systems and higher voltage solar arrays — look to Vitrek to deliver the IR tester you need for your production line.

  • Linear Power Supplies Bipolar 4-quadrant, Analog/Digital/Local Control, Ultra Low Ripple/Noise

    BOP Series - Kepco, Inc.

    Kepco's bipolar BOP power supplies are available in 100W, 200W and 400W sizes. For applications requiring higher power, see Kepco's 1KW High Power BOP. For applications requiring higher voltage, Kepco's Series BOP-HV are available in 500V and 1000V models.BOP are high speed power operational amplifiers that can be used to provide dynamically agile voltage for test and simulation. They are not general purpose power supplies. By the nature of the bipolar high speed design, they do not have any energy-storage noise discriminating output capacitors. These power supplies offer ultra low noise and ultra low ripple at the output and are MIL-STD-461 compliant.

  • *High Current Switches

    B-1002 - Ruetz Technologies GmbH

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

Get Help